Legrand / Raritan / Server Technology Xerus™ JSON-RPC API
Loading...
Searching...
No Matches
Public Attributes | List of all members
peripheral::GatewaySensorManager::InterpretationRuleModbusException Struct Reference

InterpretationRuleModbusException is applied to modbus read exceptions. More...

Inheritance diagram for peripheral::GatewaySensorManager::InterpretationRuleModbusException:
peripheral::GatewaySensorManager::InterpretationRuleInvertable peripheral::GatewaySensorManager::InterpretationRule

Public Attributes

vector< int > exceptions
 list of modbus exception codes
 
- Public Attributes inherited from peripheral::GatewaySensorManager::InterpretationRuleInvertable
boolean invertCondition
 negate rule condition
 
- Public Attributes inherited from peripheral::GatewaySensorManager::InterpretationRule
Interpretation interpretation
 how to interpret the applied rule
 
int ignoreTimeout
 if > 0, ignoring stops after this timeout (seconds), and state changes to unavailable
 

Detailed Description

InterpretationRuleModbusException is applied to modbus read exceptions.

Definition at line 441 of file GatewaySensorManager.idl.

Member Data Documentation

◆ exceptions

vector<int> peripheral::GatewaySensorManager::InterpretationRuleModbusException::exceptions

list of modbus exception codes

Definition at line 442 of file GatewaySensorManager.idl.