Raritan / Server Technology Xerus™ PDU JSON-RPC API
Modbus.idl
1 /* SPDX-License-Identifier: BSD-3-Clause */
2 /*
3  * Copyright 2011 Raritan Inc. All rights reserved.
4  */
5 
6 /**
7  * Device Settings
8  */
9 module devsettings {
10 
11  /** %Modbus service settings interface */
12  interface Modbus {
13 
14  constant int ERR_INVALID_PARAM = 1; ///< Invalid parameters
15 
16  /** Device modbus capabilities */
17  structure Capabilities {
18  boolean hasModbusSerial; ///< Device has a serial %Modbus port
19  };
20 
21  /**
22  * Retrieve the device %Modbus capabilities.
23  *
24  * @return %Modbus capbilities
25  */
27 
28  /**
29  * %Modbus/TCP settings.
30  *
31  * @note Port number and enabled flag are configured using
32  * net::Net::setNetworkConfigServices.
33  */
34  structure TcpSettings {
35  boolean readonly; ///< Disallow write requests
36  };
37 
38  /** Serial line parity */
39  enumeration Parity { NONE, EVEN, ODD };
40 
41  /** %Modbus/serial settings. */
42  structure SerialSettings {
43  boolean enabled; ///< Enable the %Modbus/RTU service
44  int baudrate; ///< Baudrate
45  Parity parity; ///< Parity
46  int stopbits; ///< Number of stop bits (1 or 2)
47  boolean readonly; ///< Disallow write requests
48  };
49 
50  /** %Modbus service settings */
51  structure Settings {
52  TcpSettings tcp; ///< %Modbus/TCP settings
53  SerialSettings serial; ///< %Modbus/serial settings
54  int primaryUnitId; ///< Main unit ID, 0 to disable
55  ///< @note Models that act as a simple Modbus device
56  ///< will ignore this setting for TCP connections and
57  ///< respond to all unit IDs.
58  };
59 
60  /**
61  * Retrieve the %Modbus service settings.
62  *
63  * @return %Modbus service settings
64  */
66 
67  /**
68  * Set the %Modbus service settings.
69  *
70  * @param settings New settings
71  *
72  * @return 0 if OK
73  * @return 1 if any parameters are invalid
74  */
75  int setSettings(in Settings settings);
76 
77  };
78 
79 }
Modbus service settings interface
Definition: Modbus.idl:12
Parity
Serial line parity.
Definition: Modbus.idl:39
Capabilities getCapabilities()
Retrieve the device Modbus capabilities.
int setSettings(in Settings settings)
Set the Modbus service settings.
Settings getSettings()
Retrieve the Modbus service settings.
Device Settings.
Definition: Crestron.idl:9
Device modbus capabilities.
Definition: Modbus.idl:17
boolean hasModbusSerial
Device has a serial Modbus port.
Definition: Modbus.idl:18
Modbus/serial settings.
Definition: Modbus.idl:42
int stopbits
Number of stop bits (1 or 2)
Definition: Modbus.idl:46
boolean readonly
Disallow write requests.
Definition: Modbus.idl:47
int baudrate
Baudrate.
Definition: Modbus.idl:44
Parity parity
Parity.
Definition: Modbus.idl:45
boolean enabled
Enable the Modbus/RTU service.
Definition: Modbus.idl:43
Modbus service settings
Definition: Modbus.idl:51
SerialSettings serial
Modbus/serial settings
Definition: Modbus.idl:53
TcpSettings tcp
Modbus/TCP settings
Definition: Modbus.idl:52
int primaryUnitId
Main unit ID, 0 to disable.
Definition: Modbus.idl:54
Modbus/TCP settings.
Definition: Modbus.idl:34
boolean readonly
Disallow write requests.
Definition: Modbus.idl:35